Use NVIDIA Sync clustering so larger models and training can span nodes.
| Symptom | Cause | Fix |
|---|---|---|
| A device does not appear in NVIDIA Sync | The device is off, on another network, or cannot accept SSH connections | Turn on the device. Make sure it and the computer that runs NVIDIA Sync are on the same local network. Test direct SSH access. |
| The GB10 check fails | The selected system is not a DGX Spark or GB10 device | Remove the unsupported system from the cluster. Cluster Assistant supports only DGX Spark and GB10 devices. |
| The software check fails | A device has an old system release | Update each device. Cluster Assistant requires the April 2026 system release or later. |
| The password check fails | NVIDIA Sync cannot use sudo on a device | Select Fix Now and enter the device password. Check that the user has sudo access. |
| Cluster Assistant finds the wrong layout | A cable is loose, the layout is not supported, or the Spark-facing switch ports are not on the same Layer 2 network | Reseat each cable and compare the links with Connect the Devices. Do not mix direct and switch links. For a switch, check that every Spark-facing port is up and on the same Layer 2 network. Then run the layout check again. |
| A switch link is down or is not 200 Gbit/s | The cable is not supported, the switch port uses the wrong mode, or the two ends do not agree on link settings | Check the cable and port mode. A 400 Gbit/s port may need to be split into two 200 Gbit/s ports. If the link stays down, check auto-negotiation and FEC in the switch maker's guide. |
| The cluster connects but data transfer is slow | A link can report 200 Gbit/s while the switch sends traffic through its CPU or the link records errors | Check hardware-offload status, switch CPU use, and port error counters. Test traffic in both directions. If the issue remains, contact the switch maker or NVIDIA support. |
| SSH setup times out | One device took more than five minutes | Retry the SSH step in Cluster Assistant. |
For more Cluster Assistant help, see the NVIDIA Sync troubleshooting guide.
These commands use the external setup-cluster.sh helper described in Configure Manually. Run them from its repository folder on the head node, as your normal login user. If NVIDIA Sync has already configured the cluster successfully, continue to your workload playbook; do not run manual setup just to check prerequisites.
| Symptom | Cause | Fix |
|---|---|---|
| The manual dry run fails | A management IP, SSH login, password, sudo setting, or required package is wrong or missing | Check the requirements in Configure Manually, test SSH to each management IP, and rerun the command for your layout with --dry-run. Supply the management IPs directly to ./setup-cluster.sh, with the head node first and the documented --topology and --mtu. |
| No ConnectX-7 interface is up | A cable or port is not active | Reseat the cables, confirm the layout, reboot the devices, and run ibdev2netdev again. |
| Verification fails after manual setup | A saved file, address, route, MTU, link, SSH setting, or Docker permission differs from the expected configuration | Open a new login session on each device, then run ./setup-cluster.sh --doctor --dry-run from the head node to inspect the issues. Review the proposed repairs before running ./setup-cluster.sh --doctor. |
| You need to undo manual setup or change the layout | The helper's changes must be reversed before a new setup | Run ./setup-cluster.sh --restore on the same head node as the same user. Keep the head node's restore manifest and every device's backups available, and ensure all devices are reachable over the management LAN. This restore uses backups from the manual helper; it does not undo an NVIDIA Sync setup. |